{"id":1045,"date":"2025-02-19T15:26:33","date_gmt":"2025-02-19T15:26:33","guid":{"rendered":"https:\/\/flowrates.com\/boutique\/uncategorized\/diaphragm-control-valve\/"},"modified":"2025-04-14T15:30:07","modified_gmt":"2025-04-14T15:30:07","slug":"diaphragm-control-valve","status":"publish","type":"product","link":"https:\/\/flowrates.com\/en\/water\/diaphragm-control-valve\/","title":{"rendered":"Diaphragm Control Valve"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"1045\" class=\"elementor elementor-1045 elementor-363\" data-elementor-settings=\"{&quot;element_pack_global_tooltip_width&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_width_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;element_pack_global_tooltip_padding&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_padding_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true},&quot;element_pack_global_tooltip_border_radius_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;top&quot;:&quot;&quot;,&quot;right&quot;:&quot;&quot;,&quot;bottom&quot;:&quot;&quot;,&quot;left&quot;:&quot;&quot;,&quot;isLinked&quot;:true}}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1033da5 e-flex e-con-boxed e-con e-parent\" data-id=\"1033da5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23f5261 elementor-widget elementor-widget-text-editor\" data-id=\"23f5261\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Technical Features of Flowrates Control Valves<\/h2><ul><li>Hydraulic testing according to <strong>EN1074-5<\/strong>;<\/li><li>Compliance with <strong>EN 1074-5 and EN 1074-1<\/strong>;<\/li><li>Parts in contact with the water comply with <strong>DM 174 of 6\/04\/2004<\/strong> and <strong>KTW, DVGW W270, WRAS<\/strong> standards;<\/li><li>Face to face according to <strong>EN 558 Series 1<\/strong>;<\/li><li>Flanges dimensioned and drilled according to <strong>EN 1092-2<\/strong>;<\/li><li><strong>Internal\/external FBE<\/strong> coating protection (Fusion Bonded Epoxy), <strong>blue RAL5015<\/strong>, <strong>250 \u03bcm<\/strong> thickness.<\/li><\/ul><h2>Operating Limits and Applications for Control Valves<\/h2><p>Valves are designed and manufactured to operate with drinking or industrial water without suspended solids. For any other use, please contact the manufacturer.<\/p><ul><li><strong>Working temperature<\/strong>: (water temp.) <strong>min. +0\u00b0C<\/strong> (excluding frost) <strong>max. +70\u00b0C<\/strong> <strong>(on request up to 90\u00b0C).<\/strong><\/li><li><strong>Storage temperature<\/strong>: (air temp.): <strong>min. -20\u00b0C, max. +70\u00b0C.<\/strong><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Automatic control valves, as described by EN 1074-5, \u201chave the integral capability to control the function using energy from the conveyed water <strong>by adjusting the position of the obturator<\/strong>.<br \/>\nThey can be directly operated, i.e. the force is applied (via a spring or diaphragm) directly to the obturator. They can be pilot operated, i.e. the force is applied through an adjustable pilot valve\u201d.<\/p>\n<p>This type of conveyed flow valves is the result of years of study, design and research carried out by <strong>T.I.S Nuoval<\/strong> over the years, both internally and directly on the plants.<\/p>\n<p>These valves are available in sizes from <strong>DN50 <\/strong>to <strong>DN1000<\/strong>, <strong>flanges <\/strong>to EN 1092-2, with nominal pressures <strong>PN10 &#8211; PN16 &#8211; PN25<\/strong>.<\/p>\n<p><strong>These valves can be built as :<\/strong><\/p>\n<ul>\n<li>Pressure reducing valves<\/li>\n<li>Pressure sustaining valves<\/li>\n<li>Altimetric valves<\/li>\n<li>Float controlled valves<\/li>\n<\/ul>\n","protected":false},"featured_media":904,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-1045","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-water","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product\/1045","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/comments?post=1045"}],"version-history":[{"count":3,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product\/1045\/revisions"}],"predecessor-version":[{"id":1372,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product\/1045\/revisions\/1372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/media\/904"}],"wp:attachment":[{"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/media?parent=1045"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product_brand?post=1045"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product_cat?post=1045"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/flowrates.com\/en\/wp-json\/wp\/v2\/product_tag?post=1045"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}